Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Einstein (Säo Paulo) ; 16(4): eAO4279, 2018. tab, graf
Article in English | LILACS | ID: biblio-975095

ABSTRACT

ABSTRACT Objective To evaluate safety and effectiveness of nodule volume reduction and thyroid function after percutaneous laser ablation treatment in patients with benign nonfunctioning thyroid nodules. Methods Prospective single-center study, from January 2011 to October 2012, which evaluated 30 euthyroid and thyroid antibodies negative patients with benign solitary or dominant nodule with indication of treatment due to compressive symptoms and aesthetic disturbances. The clinical and laboratory (thyroid ultrasound, TSH, FT4, TG, TG-Ab, TPO-Ab and TRAb levels) evaluations were performed before the procedure, and periodically 1 week, 3 months and 6 months after. The ablation technique was performed under local anesthesia and sedation. In each treatment, one to three 21G spinal needle were inserted into the thyroid nodule. The laser fiber was positioned through the needle, which was then withdrawn 10mm to leave the tip in direct contact with the nodule tissue. Patients were treated with a ND: Yag-laser output power of 4W and 1,500 to 2,000J per fiber per treatment. The entire procedure was performed under US guidance. Results Thirty patients, with a total of 31 nodules submitted to laser ablation were evaluated. The median volumetric reduction of the nodule was approximately 60% after 12 months. No statistical significance was observed on thyroid function and antibodies levels. There was a peak on the level of thyroglobulin after the procedure due to tissue destruction (p<0.0001). No adverse effects were observed. Conclusion Percutaneous laser ablation is a promising outpatient minimally invasive treatment of benign thyroid nodule.


RESUMO Objetivo Avaliar a segurança e a efetividade da redução de volume nodular e função tireoidiana após tratamento com ablação percutânea por laser em pacientes com nódulos tireoidianos benignos não funcionantes. Métodos Estudo unicêntrico prospectivo, de janeiro de 2011 a outubro de 2012, que avaliou 30 pacientes eutireoideos (com anticorpos antitireoide negativos), com nódulo solitário ou dominante benigno, com indicação de tratamento devido a sintomas de compressão e distúrbios estéticos. As avaliações clínica e laboratorial (ultrassonografia de tireoide, TSH, FT4, TG, TG-Ab, TPO-Ab e TRAb) foram realizada antes do procedimento e periodicamente − 1 semana, 3 meses e 6 meses depois. A técnica de ablação consistiu em procedimento realizado sob a anestesia local e sedação. Em cada tratamento, uma a três agulhas espinhais 21G foram inseridas no nódulo tireoidiano. A fibra laser foi posicionada através da agulha que foi, então, retirada 10mm, para deixar a ponta em contato direto com o nódulo. Os pacientes foram tratados com uma potência de saída ND: Yag-laser de 4W e 1.500 a 2.000J por fibra por tratamento. Todo o procedimento foi guiado por ultrassonografia. Resultados Foram avaliados 30 pacientes, com total de 31 nódulos submetidos à ablação a laser. A redução média volumétrica do nódulo foi de aproximadamente 60% após 12 meses. Não foi observada significância estatística na função da tireoide e nem nos níveis de anticorpos. Houve pico no nível de tiroglobulina após o procedimento devido à destruição do tecido (p<0,0001). Nenhum efeito adverso foi observado. Conclusão A ablação com laser é um tratamento minimamente invasivo promissor para tratamento do nódulo benigno da tireoide.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Thyroid Nodule/surgery , Laser Therapy/methods , Organ Size , Pain, Postoperative , Autoantibodies/blood , Thyroxine/blood , Calcitonin/blood , Thyrotropin/blood , Prospective Studies , Follow-Up Studies , Treatment Outcome , Thyroid Nodule/pathology , Thyroid Nodule/blood , Laser Therapy/adverse effects
2.
Einstein (Säo Paulo) ; 14(2): 119-123, tab, graf
Article in English | LILACS | ID: lil-788034

ABSTRACT

ABSTRACT Objective To correlate the Thyroid Imaging Reporting and Data System (TI-RADS) and the Bethesda system in reporting cytopathology in 1,000 thyroid nodules. Methods A retrospective study conducted from November 2011 to February 2014 that evaluated 1,000 thyroid nodules of 906 patients who underwent ultrasound exam and fine needle aspiration. Results A significant association was found between the TI-RADS outcome and Bethesda classification (p<0.001). Most individuals with TI-RADS 2 or 3 had Bethesda 2 result (95.5% and 92.5%, respectively). Among those classified as TI-RADS 4C and 5, most presented Bethesda 6 (68.2% and 91.3%, respectively; p<0.001). The proportion of malignancies among TI-RADS 2 was 0.8%, and TI-RADS 3 was 1.7%. Among those classified as TI-RADS 4A, proportion of malignancies was 16.0%, 43.2% in 4B, 72.7% in 4C and 91.3% among TI-RADS 5 (p<0.001), showing clear association between TI-RADS and biopsy results. Conclusion The TI-RADS is appropriate to assess thyroid nodules and avoid unnecessary fine needle aspiration, as well as to assist in making decision about when this procedure should be performed.


RESUMO Objetivo Apresentar a correlação entre o Thyroid Imaging Reporting and Data System (TI-RADS) e o sistema Bethesda, para relatar citopatologia em 1.000 nódulos tireoidianos. Métodos Estudo retrospectivo realizado no período de novembro de 2011 a fevereiro de 2014, que avaliou 1.000 nódulos tireoidianos de 906 pacientes submetidos a exame de ultrassonografia e à punção aspirativa por agulha fina. Resultados Observou-se associação significativa entre o TI-RADS e o resultado da classificação de Bethesda (p<0,001). A maioria dos indivíduos com TI-RADS 2 ou 3 teve resultado citológico Bethesda 2 (95,5% e 92,5%, respectivamente). Entre aqueles classificados TI-RADS 4C e 5, a maioria teve resultado Bethesda 6 (68,2% e 91,3%, respectivamente; p<0,001). A proporção de malignidades em TI-RADS 2 foi 0,8% e em TI-RADS 3 foi 1,7%. Entre TI-RADS 4A, foi de 16,0%, 43,2% em 4B, 72,7% em 4C e em 5 foi de 91,3% (p<0,001), mostrando clara associação entre o TI-RADS e os resultados da biópsia. Conclusão O TI-RADS é apropriado para avaliar nódulos da tireoide e evitar punção aspirativa por agulha fina desnecessária, além de auxiliar na decisão sobre quando este procedimento deve ser realizado.


Subject(s)
Humans , Thyroid Gland/pathology , Thyroid Gland/diagnostic imaging , Ultrasonography , Thyroid Nodule/pathology , Thyroid Nodule/diagnostic imaging , Biopsy, Fine-Needle , Retrospective Studies , Ultrasonography/statistics & numerical data , Thyroid Nodule/classification , Diagnosis, Differential
3.
Einstein (Säo Paulo) ; 9(1)jan.-mar. 2011. tab
Article in English, Portuguese | LILACS | ID: lil-583365

ABSTRACT

Objective: To evaluate the impact of screening hyper and hypoglycemia measured by capillary glycemia and standard monitorization of hyperglycemic patients hospitalized in regular care units of Hospital Israelita Albert Einstein. Methods: The capillary glycemia was measured by the Precision PCx (Abbott) glucosimeter, using the PrecisionWeb (Abbott) software. The detection of hyper and hypoglycemia during the months of May/June were compared to those of March/April in 2009 and to the frequency of the diagnosis of diabetes in 2007. Results: There was an increase in the glycemia screening from 27.7 to 77.5% of hospitalized patients (p < 0.001), of hyperglycemia detection (from 9.3 to 12.2%; p < 0.001) and of hypoglycemia (from 1.5 to 3.3%; p < 0.001) during the months of May/June 2009. According to this action 14 patients for each additional case of hyperglycemia and 26 cases for each case of hypoglycemia were identified. The detection of hyperglycemia was significantly higher (p < 0.001) than the frequency of registered diagnosis related do diabetes in the year of 2007. Conclusions: the adoption of an institutional program of glycemia monitorization improves the detection of hyper and hypoglycemia and glycemia control in hospitalized patients in regular care units.


Objetivo: Analisar o impacto do rastreamento de hiper e hipoglicemia mensurada por glicemia capilar e da monitorização padronizada em pacientes hiperglicêmicos internados em unidades não graves do Hospital Israelita Albert Einstein. Métodos: A glicemia capilar foi mensurada com glucosímetro Precision PCx (Abbott), rastreada com software PrecisionWeb (Abbott). A detecção de hiper e hipoglicemia no bimestre Maio/Junho foi comparada ao bimestre Março/Abril de 2009 e ainda quanto à frequência de diagnósticos relacionados ao diabetes no ano de 2007. Resultados: Houve um aumento do rastreamento de glicemia de 27,7 para 77,5% dos pacientes internados (p < 0,001), na detecção de hiperglicemia (de 9,3 para 12,2%; p < 0,001) e de hipoglicemia (de 1,5 para 3,3%; p < 0,001) no bimestre Maio-Junho de 2009. Com essa iniciativa, foram rastreados 14 pacientes para cada caso adicional de hiperglicemia e 26 pacientes para cada caso de hipoglicemia. A detecção de hiperglicemia foi significantemente maior (p < 0,001) que a frequência de registros de diagnósticos relacionados ao diabetes no ano de 2007. Conclusões: a adoção de um programa institucional de monitoramento de glicemia melhora a detecção de hiper e hipoglicemia e o controle de glicemia em pacientes internados em unidades não graves.


Subject(s)
Blood Glucose , Hyperglycemia/diagnosis , Hypoglycemia/diagnosis , Inpatients
4.
Arq. bras. endocrinol. metab ; 55(1): 29-37, Feb. 2011. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-580292

ABSTRACT

OBJETIVO: Avaliar risco de malignidade de nódulos tiroidianos por meio de aspectos clínicos, laboratoriais, ultrassonográficos e citológicos. PACIENTES E MÉTODOS: 741 nódulos de 407 pacientes. RESULTADOS: A citologia foi benigna (60,5 por cento), indeterminada (23,3 por cento), maligna (8,6 por cento) ou não diagnóstica (7,6 por cento). A prevalência de câncer nas citologias indeterminadas foi 18,5 por cento (16 por cento nas lesões foliculares, 44 por cento nas suspeitas). O diagnóstico de malignidade foi 17,2 por cento (n = 70). A frequência de câncer em mulheres (15,2 por cento) foi menor do que em homens (27,9 por cento). Houve uma relação inversa entre idade e risco de câncer. Não houve significância estatística na prevalência de câncer de acordo com número, tamanho dos nódulos ou níveis de TSH. Hipoecogenicidade e microcalcificações ao ultrassom foram fatores de risco. CONCLUSÃO: O risco de malignidade foi maior em homens, nódulos hipoecogênicos, com microcalcificações e inversamente relacionado à idade. O nível de TSH não foi um preditor independente de malignidade.


OBJECTIVE: To evaluate the risk of malignancy in thyroid nodules through clinical, laboratory, ultrasonographic and cytological aspects. PATIENTS AND METHODS: 741 nodules of 407 patients. RESULTS: The cytology was benign (60,5 percent), indeterminate (23,3 percent), malignant (8,3 percent) or nondiagnostic (7,6 percent). The prevalence of cancer in indeterminate citology was 18,5 percent (16 percent in follicular lesions, 44 percent in suspicious). The diagnosis of malignancy was 17,2 percent (n = 70). The frequency of cancer in women (15,2 percent) was lower than in men (27,9 percent). There was an inverse relation between age and cancer risk. There was no statistical significance in the prevalence of cancer according to number, size of nodules or TSH levels. Hypoechogenicity and microcalcifications on ultrasound were risk factors. CONCLUSION: The risk of malignancy was higher in men, hypoechoic nodules, with microcalcifications and was inversely related to age. The TSH level was not an independent factor predictive of malignancy.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Young Adult , Calcinosis/diagnosis , Carcinoma/diagnosis , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Biopsy, Fine-Needle/methods , Calcinosis/pathology , Calcinosis , Carcinoma/epidemiology , Carcinoma/pathology , Epidemiologic Methods , Thyroid Gland/pathology , Thyroid Gland , Thyroid Neoplasms/epidemiology , Thyroid Neoplasms/pathology , Thyroid Nodule/pathology , Thyroid Nodule
SELECTION OF CITATIONS
SEARCH DETAIL